OH Consultant
Australia Manufacturing/Perth

Welding Fume in ManufacturingPerth

Perth's fabrication and engineering workshop sector supplies structural and mechanical components to the mining, oil and gas, marine, and defence industries. The welding fume WEL drops fivefold from 5 to 1 mg/m³ from December 2026. Perth's Henderson shipbuilding and marine precinct is a major welding-intensive industrial zone.

4 Key Hazards Monitored

Perth Local Context

Perth's fabrication workshops are concentrated in Henderson (marine and defence), Welshpool (general engineering), Kwinana (heavy industry), and Malaga (light fabrication). The mining services sector drives high-volume fabrication of structural steel, pressure vessels, pipe spools, and equipment housings — all involving sustained MIG, TIG, and stick welding. Henderson's shipbuilding precinct handles naval construction and commercial marine fabrication with stainless steel and aluminium welding that generates elevated Cr(VI), Ni, and Mn fume. Workshop conditions range from well-ventilated modern facilities to older buildings with limited extraction.

WorkSafe WA (DMIRS) Enforcement

Work Health and Safety Act 2020 (WA), WHS (General) Regulations 2022 (WA)

Category 1: up to $3.5 million (body corporate)

Welding fume WEL drops to 1 mg/m³ from December 2026

Major Project Types in Perth

Mining services fabrication (structural steel, pressure vessels)
Marine and naval fabrication (Henderson precinct)
General engineering workshops (Welshpool, Malaga)
Oil and gas component fabrication

Key Hazards

Primary exposure hazards requiring monitoring in Perth.

MIG and FCAW welding in fabrication

weld

Metal Inert Gas (MIG) and Flux-Cored Arc Welding (FCAW) are the dominant processes in manufacturing fabrication workshops. FCAW in particular generates high fume emission rates due to the flux decomposition. Workshop environments with multiple welding bays operating simultaneously create cumulative background fume levels that affect all workers in the space, not just the welders themselves.

Stainless steel welding and Cr(VI) generation

weld

Welding stainless steel by any process generates hexavalent chromium Cr(VI) in the fume. Cr(VI) has a WES of 0.05 mg/m³ TWA and is a confirmed lung carcinogen and respiratory sensitiser. TIG welding on stainless steel generates lower total fume mass but a higher percentage of Cr(VI) relative to total fume. Separate filter cassettes are required for Cr(VI) analysis to prevent reduction to Cr(III) during storage.

Manganese in mild steel fume

weld

Mild steel welding fume contains manganese at 5-15% of total fume mass. The WES for manganese is 1 mg/m³ TWA inhalable fraction. Chronic overexposure causes manganism, a progressive neurotoxic condition. Manufacturing welders performing full-shift welding on mild steel are at elevated risk of exceeding the manganese WES even when total fume levels appear moderate.

Confined and semi-enclosed welding

weld

Fabrication of tanks, vessels, hoppers, and large assemblies requires welders to work inside or partially inside the structure. Fume concentrations inside semi-enclosed fabrications can be 5 to 10 times higher than open workshop levels. Portable LEV or on-torch extraction must be assessed for effectiveness in these configurations.

Common Analytes

Substances typically included in occupational hygiene sampling proposals for this sub-category.

AnalyteCASRelevance
Welding Fume (total, inhalable)Current WES 5 mg/m³ TWA inhalable fraction. Transitioning to 1 mg/m³ from 1 December 2026. IOM sampler with 25 mm MCE filter.
Hexavalent Chromium Cr(VI)18540-29-9WES 0.05 mg/m³ TWA. IARC Group 1 carcinogen. Separate PVC filter cassette with alkaline stabiliser required. Mandatory for all stainless steel welding assessments.
Manganese (Mn)7439-96-5WES 1 mg/m³ TWA inhalable fraction. Neurotoxic. Primary metal fume component from mild and carbon steel welding.
Nickel (Ni)7440-02-0WES 1 mg/m³ TWA inhalable fraction. IARC Group 1 carcinogen (nickel compounds). Present in stainless steel and nickel alloy welding fume.
Iron Oxide (Fe₂O₃)1309-37-1WES 5 mg/m³ TWA respirable fraction. Major component of mild steel welding fume. Siderosis (iron pneumoconiosis) from chronic overexposure.

Typical Worker Groups

Common similar exposure groups (SEGs) assessed for this sub-category.

MIG/FCAW welders (mild steel)TIG welders (stainless steel)Stick welders (SMAW)Welding assistants and fittersGrinders and finishers (adjacent to welding)Workshop bystanders (background fume exposure)Quality inspectors (entering welded fabrications)

Regulatory Context

Safe Work Australia published the Welding Processes Code of Practice in 2019 following the IARC Group 1 reclassification of welding fume. The code requires all welding fume to be captured at source or controlled to below the WES using engineering controls as the primary measure, with RPE as supplementary only. From 1 December 2026, the WES for welding fume (not otherwise specified) reduces from 5 mg/m³ to 1 mg/m³ inhalable fraction. Health monitoring is required for workers with significant welding fume exposure, including respiratory function testing and a medical assessment by a registered medical practitioner with experience in occupational health. The WHS Regulation also requires health monitoring for hexavalent chromium under Schedule 14.

Related Sub-Categories

Other monitoring services in Perth.

Solvent Exposure Monitoring

Personal air monitoring for organic solvent vapours during spray painting, degreasing, coating appli...

Noise Monitoring in Manufacturing

Personal noise dosimetry and area noise surveys in manufacturing environments with CNC machines, hyd...

Isocyanate Monitoring

Personal air monitoring for methylene diphenyl diisocyanate (MDI) and toluene diisocyanate (TDI) dur...

Wood Dust Monitoring

Personal air monitoring for inhalable wood dust in joinery, cabinet making, furniture manufacturing,...

Available in Other Locations

Melbourne \→Sydney \→Brisbane \→Adelaide \→View national page \→

Ready to discuss your monitoring requirements?

Our qualified occupational hygienists will review your situation and provide a tailored sampling proposal within 48 hours.